Mitsubishi Heavy Industries 10kW Inverter Ducted System FDU100VNPWVH

Mitsubishi Heavy Industries

Mitsubishi Heavy Industries 10kW Inverter Ducted System FDU100VNPWVH

Sale price$3,059.00
No reviews
No reviews
MODEL: FDU100VH / FDC100VNP-W
Quantity:
Found a better price?

Ducted & Split Systems Sizing Calculator

Use our split system or ducted sizing calculator below to determine the minimum size required for your room or house.

Note: For ducted systems only include the air conditioned spaces, exclude areas like garages, bathrooms or laundries.

 

Overview

Mitsubishi Heavy Industries FDU100VH / FDC100VNP-W 10kW High Static Ducted System | Single Phase

Indoor: FDU100VH

Outdoor: FDC100VNP-W

Backlit Controller: RC-EXZ3A

Specifications

CAPACITY 10.0KW
Set FDU100VNPWVH
Indoor FDU100VH
Outdoor FDC100VNP-W
Power Source (Outdoor Unit) 1 Phase 240V 50Hz
 

 

 

 

 

 

 

 

 

 

*Operation Data

 

 

Nominal Capacity Range

Cooling T1  

 

 

 

kW

10 (2.1-10.2)
Heating H1 10 (1.7-10.4)
Heating H2 7.60
 

 

Power Consumption

Cooling T1 3.08
Heating H1 2.45
Max Power Consumption 4.46
 

 

Running Current

Cooling T1  

 

A

13.1
Heating H1 10.4
Inrush Current, Maximum Current 5, 19
EER Cooling T1 3.25
COP Heating H1 4.08
Sound Power Level (JS C9612) Outdoor  

 

 

dB(A)

68
Sound Pressure Level (JS C9612) Indoor P-Hi: 44 Hi: 38

 

Me: 36 Lo: 30

Outdoor 56
 

 

External Dimensions (HXWXD)

Indoor  

 

mm

280x1370x740
Outdoor 750 × 880(+88) × 340
 

 

Net Weight

Indoor  

 

Kg

54
Outdoor 57
Supply Air Connection  

 

mm

170×1200
Return Air Connection 235×1280
External Static Pressure (Max) Pa 200
Airflow Indoor (Cooling) l/s P-Hi:600 Hi:467 Me:417 Lo:317
Indoor (Heating)
 

 

Refrigerant (Type, Amount, Pre-charge Length)

Quantity kg (R32) 1.7
Pre Charged To Pipe

 

Length

m 15
 

 

 

 

Installation Data

 

 

Refrigerant Piping

Liquid Line  

 

mm

Ø6.35**
Gas Line Ø15.88
Connection Method Flare Connection
Maximum Pipe Length (One Way)  

 

m

30
 

 

Max vertical height diff. between O.U. and I.U.

20 ( O.U. above I.U. ) /

 

20 ( O.U. below I.U. )

Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Motion Sensor (Optional) LB-KIT2
Demand response (AS4755) No
Outdoor air temperature (upper, lower limits) Cooling  

 

oC

-15 to 46
Heating -15 to 20

NEED INSTALLATION QUOTE?

Fast Aus Wide Delivery

Most deliveries dispatched locally