Fujitsu SET-AUTH54KRTA-T5 13kW Inverter Cassette Split Systems 1 Phase | R32

Fujitsu

Fujitsu SET-AUTH54KRTA-T5 13kW Inverter Cassette Split Systems 1 Phase | R32

Sale price$5,174.00
No reviews
No reviews
MODEL: SET-AUTH54KRTA-T5
Quantity:
Found a better price?

Ducted & Split Systems Sizing Calculator

Use our split system or ducted sizing calculator below to determine the minimum size required for your room or house.

Note: For ducted systems only include the air conditioned spaces, exclude areas like garages, bathrooms or laundries.

 

Overview

Fujitsu SET-AUTH54KRTA-T5 13kW Inverter Cassette Split Systems 1 Phase

The Fujitsu SET-AUTH54KRTA-T5 13kW Inverter Cassette Split System provides powerful cooling and heating for larger spaces. Designed for single-phase power supply, this system utilises R32 refrigerant to ensure high energy efficiency and reduced environmental impact. It includes the AUTH54KRTA indoor unit and AOTH54KBTA outdoor unit, complemented by a grille UTG-UKTB-W and a wired controller UTY-RNRYT5 for precise control. Ideal for residential and commercial applications, it offers reliable year-round comfort and performance.

Specifications

Indoor unit AUTH54KRTA
Outdoor unit AOTH54KBTA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max)) 13.00 (4.5 – 15)
Heating Capacity kW (Rated (Min – Max)) 15.50 (4.7 – 18)
Input Power Cooling kW (Rated (Min – Max)) 4.04 (5.19)
Input Power Heating kW (Rated (Min – Max)) 4.07 (5.23)
EER Cooling kW/kW 3.22
COP Heating kW/kW 3.81
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 3
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.662 / 4.454 / 4.722
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.997 / 5.185 / 5.598
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.997 / 5.185 / 5.598
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.937 / 4.239 / 3.65
Running Current amps (Cooling / Heating) 18.1 / 17.8
Moisture Removal l/hr 5
Indoor Sound Pressure Cooling dBA (High / Quiet) 47 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 47 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 55 / 57
Outdoor Sound Power dBA 72
Air Circulation (Indoor – High Fan) Cooling l/sec 556
Air Circulation (Indoor – High Fan) Heating l/sec 556
Indoor Unit Dimensions mm (Height x Width x Depth) 288 x 840 x 840
Indoor Unit Weight kg 29
Outdoor Unit Dimensions mm (Height x Width x Depth) 998 x 940 x 320
Outdoor Unit Weight kg 67
Grill Weight 6
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (30)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32
Refrigerant Amount g 2,700