Fujitsu SET-AUTH45KRTA-3PH-YC 12.5kW Inverter Cassette Split Systems 3 Phase | R32

Fujitsu

Fujitsu SET-AUTH45KRTA-3PH-YC 12.5kW Inverter Cassette Split Systems 3 Phase | R32

Sale price$5,282.00
No reviews
No reviews
MODEL: SET-AUTH45KRTA-3PH-YC
Quantity:
Found a better price?

Ducted & Split Systems Sizing Calculator

Use our split system or ducted sizing calculator below to determine the minimum size required for your room or house.

Note: For ducted systems only include the air conditioned spaces, exclude areas like garages, bathrooms or laundries.

 

Overview

Fujitsu SET-AUTH45KRTA 12.5kW Inverter Cassette Split System

The Fujitsu SET-AUTH45KRTA 12.5kW Inverter Cassette Split System is designed for powerful performance and efficiency. With a robust 3-phase power supply, it delivers 12.5kW of cooling and 14kW of heating, ensuring optimal comfort in both residential and commercial settings. The system features a reverse cycle operation, advanced moisture removal, and quiet indoor operation, making it a reliable choice for Australian climates. Equipped with R32 refrigerant and a high-performance grille, it provides precision climate control with minimal environmental impact.

Indoor Unit: AUTH45KRTA
Outdoor Unit: AOTH45KRTA
Grille: UTG-UKTB-W
Wired Controller: UTY-LBTYC

Specifications

Indoor unit

AUTH45KRTA

Outdoor unit AOTH45KRTA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 400 / 3 / 50
Cooling Capacity kW (Rated (Min – Max)) 12.50 (4 – 14)
Heating Capacity kW (Rated (Min – Max)) 14.00 (4.2 – 16.5)
Input Power Cooling kW (Rated (Min – Max)) 3.89 (4.9)
Input Power Heating kW (Rated (Min – Max)) 3.89 (4.9)
EER Cooling kW/kW 3.21
COP Heating kW/kW 4.07
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 3 / 3
Star Rating Heating (0-10) (Hot / Average / Cold) 3.5 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.764 / 4.548 / 4.842
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.119 / 5.331 / 5.773
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.119 / 5.331 / 5.773
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.139 / 4.658 / 4.043
Running Current amps (Cooling / Heating) 6.4 / 5.5
Moisture Removal l/hr 4.8
Indoor Sound Pressure Cooling dBA (High / Quiet) 46 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 46 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 55 / 57
Outdoor Sound Power dBA 71
Air Circulation (Indoor – High Fan) Cooling l/sec 542
Air Circulation (Indoor – High Fan) Heating l/sec 542
Indoor Unit Dimensions mm (Height x Width x Depth) 288 x 840 x 840
Indoor Unit Weight kg 29
Outdoor Unit Dimensions mm (Height x Width x Depth) 998 x 940 x 320
Outdoor Unit Weight kg 67
Grill Weight 6
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (30)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32
Refrigerant Amount g 2,180