| Model No. – Outdoor | AOTG24LAT3 |
| Reverse Cycle System | Yes |
| Cooling Capacity (Watts) | 6800 |
| Cooling Capacity (BTU/h) | 23200 |
| Range (Watts) | 1800-8500 |
| Range (BTU/h) | 6100-29000 |
| Heating Capacity (Watts) | 8000 |
| Heating Capacity (BTU/h) | 27300 |
| Range (Watts) | 2000-9200 |
| Range (BTU/h) | 6800-31400 |
| Power Supply (Volts) | 240 |
| Phase-Frequency (Ph – Hz) | 1-50 |
| Power Supply Attachment | Outdoor |
| Plug Size (If Applicable) | NA |
| Running Current, Cooling (Amps) | 8.1 |
| Running Current, Range (Amps) | Max 10.9 |
| Running Current, Heating (Amps) | 8.4 |
| Running Current, Range (Amps) | Max 12.1 |
| Input, Cooling (Watts) | 1940 |
| Input, Range (Watts) | Max 2600 |
| Input, Heating (Watts) | 2000 |
| Input, Range (Watts) | Max 2870 |
| E.E.R. – Cooling | 3.5 |
| C.O.P. – Heating | 4 |
| Fan Speed | 2 |
| Air Circulation, High (l/s) | 917 |
| Compressor Type | DC twin Rotary |
| Dimensions | 620x790x290 |
| Indoor Unit Hole Cutout Size (mm) | 55 |
| O.U. Sound Pressure Level (dBA @1mtr) | 48 |
| O.U. Sound Power Level (dBA) | 64 |
| Refrigerant Type | R410A |
| Connection Pipe Sizes, Gas (mm) | 2 X 9.52, 1 X 12.7 |
| Connection Pipe Sizes, Liquid (mm) | 3 X 6.35 |
| Pre Charged Length (Metre) | 30 |
| Minimum Pipe Length (Metre) | 15 |
| Maximum Pipe Length per unit (Metre) | 25 |
| Maximum Pipe Height (Metre) | 15 (IU TO OU) |
| Pipe Connection Methods | Flare |
| Outdoor operating Temp, Cooling ℃ | -10 to 46 |
| Outdoor operating Temp, Heating ℃ | -15 to 24 |
Overview
Fujitsu 6.8kW Multi Head Outdoor Unit Only AOTG24LAT3 - Reverse Cycle
Fujitsu Reverse Cycle (R410A) Outdoor Unit Only AOTG24LAT3
6.8kW Cooling – 8kW Heating capacity
Max Connectable indoor units: 3