Experience superior climate control with the Actron Air CRE-071AS/URC-071AS 7.1kW Cassette Split System. This robust system offers 7.1kW of cooling and 7.85kW of heating power, perfect for maintaining comfort in any season. With a sleek design and premium wired controller, it seamlessly integrates into any space, providing efficient and reliable performance. Ideal for both residential and commercial applications, this system ensures year-round comfort with advanced inverter technology.
Indoor: CRE-071AS
Outdoor: URC-071AS
Specifications
Technical Information | ||
OUTDOOR MODEL | URC-071AS | |
INDOOR MODEL | CRE-071AS | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.1) | Cooling (min max) | 7.10 (2.80 - 8.40) |
Heating (min max) | 7.85 (3.00 - 9.00) | |
Input Power (kW) (AS/NZS3823.1.1) | Cooling Rated | 2.11 |
Heating Rated | 2.25 | |
EER Rated (AS/NZS3823.1.1) COP Rated (AS/NZS3823.1.1) | Cooling | 3.36 |
Heating | 3.49 | |
Star Rating (AS/NZS3823.1.1) | Cooling | 2.0 |
Heating | 2.0 | |
Power Supply (V / Ph / Hz) | Outdoor | 220 240 V / 1Ph+N / 50Hz |
Rated Load Amps (AS/NZS3823.1.1) | Cooling | 9.4 |
Heating | 10.0 | |
Full Load Amps (AS/NZS3823.1.1) | 17.5 | |
Circuit Breaker Amps | 20.0 | |
Suggested Minimum Mains Cable Size | 2.5mm2 | |
Suggested Minimum Indoor to Outdoor Power Cable Size & Type | 1.0mm2 2 Core + Earth | |
IP Rating | Outdoor | IP24 |
Indoor | IP20 | |
Moisture Removal (L/hr) | 1.5 | |
Compressor Type | Inverter Twin-Rotary | |
Refrigerant | R410A | |
Airflow Range Indoor (l/s) | High | 369 |
Medium | 322 | |
Low | 386 | |
Outdoor Dimensions (mm) | Depth | 410 |
Height | 810 | |
Width | 946 | |
Indoor Dimensions (mm) | Depth | 840 |
Height | 245 | |
Width | 840 | |
Indoor Panel Dimensions (mm) | Depth | 950 |
Height | 55 | |
Width | 950 | |
Nominal Weight (kgs) | Outdoor | 61 |
Indoor | 31 | |
Indoor Sound Pressure Level (dBA) (Low / Med / High) | 40 / 44 / 47 | |
Outdoor Sound Pressure Level (dBA) 1m | 61 | |
Outdoor Sound Power Level (dBA) | 69 | |
Outdoor Operating Range (C) | Cooling | -15C to 50C |
Heating | -25C to 30C | |
MEPS Compliant | Yes | |
Demand Response Capability (AS4755.3) | Capable |